RC1 "177CFMフロートドレン用の乾燥剤エアフィルター
$230.661-19 Piece/Pieces
$219.13≥20Piece/Pieces
お支払い方法の種類: | T/T,L/C |
インコタームズ: | FOB,CIF,CFR,EXW |
輸送方法: | Ocean,Land,Air,Express |
ポート: | Shenzhen,Guangzhou ,Shanghai |
Ms. YUKA Filtration
何か私にできますか?
$230.661-19 Piece/Pieces
$219.13≥20Piece/Pieces
お支払い方法の種類: | T/T,L/C |
インコタームズ: | FOB,CIF,CFR,EXW |
輸送方法: | Ocean,Land,Air,Express |
ポート: | Shenzhen,Guangzhou ,Shanghai |
モデル: YF070
ブランド: ユカ
Filtration Grade: Medium Filter
Medium Material: Fiberglass
HSコード: 8421399090
Origin: China
Connection: Rc1"
Clapboard: Without Clapboard
Type: Cartridge Filter
Material: Aluminum Alloy
Filtration Performance: From 5 μm To 0.01μm
Operate Temperature: 1.5~80ºc
Resistance Corrosion: Inside And Outside
Transport Package: Brown Inner Box & Cardboard
Housing Serve Lige: 15 Years
Maxi. Operate Pressure: 1.0mpa
Parts: Dp Indicator, Auto Drain, Sight Glass
Efficiency: F9
Element Serve Life: 2000~3000 Hours
Element Top Cap Design: Colorful To Distinguish
Diversion Fin Design On Element Top Cap: Less Pressure Loss
Flow Rate: 5.0 M³/Min
Specification: Dimension: 138 X 111x 503mm
販売単位 | : | Piece/Pieces |
パッケージ型式 | : | カートンボックス |
写真の例 | : |
The file is encrypted. Please fill in the following information to continue accessing it
機能と利点
fillter Housing:アルミニウム合金材料、 15年間のスパンライフ作業条件温度1.5ºC〜80ºC 。マキシ。圧力は1.0 MPaです。 Cオールセンフィルター
合体フィルターは、おそらく、油蒸気と水をろ過するだけでなく、サイズが0.01ミクロンとして許容レベルのアスマルに固体微粒子をろ過するように設計された圧縮空気システムにおける純粋な浄化要件の最も重要な項目です。通常、設置システムでは、最初のフィルターの目的は、高品質を提供するために、フィルターを事前にフィルターし、バルク汚染から高効率フィルターを保護することです。
圧縮空気。エアフィルターが湿っているか、吸着状態でいっぱいになった場合、圧縮された空気が存在するのを防ぎ、空気が低いため、液体が元素媒体の毛穴から通り抜けるようになります。したがって、作業圧力低下を増やし、ろ過性能を低下させます。
アクティブ化されたカーボンフィルター
オイル蒸気は、ガス状の状態で合体フィルターを簡単に通過できるため、吸着フィルターは大きな活性炭吸着ベッドを提供する必要があります。湿った空気は活性炭の吸着能力を低下させるため、吸着剤は通常、吸着乾燥機の後に設置され、油蒸気と特異な臭気の効果的な除去を保証します。液体オイルやエアロゾルの除去には使用されていないため、維持が不十分であり、事前に不足しているため、その無効化が加速します。
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m3/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
YF010 | RC1/2" | 16.7 | 1.0 | 35.3 | 96 | 79 | 261 | 29 | 198 | 118 |
YF020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 261 | 29 | 198 | 118 |
YF030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 295 | 29 | 233 | 153 |
YF040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 295 | 29 | 233 | 153 |
YF060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 403 | 37 | 296 | 208 |
YF070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 503 | 37 | 396 | 303 |
YF080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 503 | 37 | 396 | 303 |
YF090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 736 | 58 | 607 | 469 |
YF100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 736 | 58 | 607 | 469 |
YF110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
YF120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 1016 | 58 | 887 | 794 |
YF130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 793 | 74 | 649 | 514 |
YF140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 793 | 74 | 649 | 514 |
YF150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
YF160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 1050 | 74 | 906 | 764 |
Technical requirements | Maximum operating pressure: 10 barg Operating temperature: 1.5°C~80°C. |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |