ホーム > 製品情報> 圧縮エアフィルター> アルミニウムエアフィルター> 圧縮空気処理装置市場
圧縮空気処理装置市場
圧縮空気処理装置市場
圧縮空気処理装置市場

圧縮空気処理装置市場

$125.281-19 Piece/Pieces

$119≥20Piece/Pieces

お支払い方法の種類:T/T,L/C
インコタームズ:CIF,EXW,CFR,FOB
輸送方法:Land,Ocean,Air,Express
ポート:Shenzhen,Guangzhou,Shanghai
製品の属性

モデルHFD070

OriginChina

HSコード8421399090

ClapboardWithout Clapboard

Filter Number1

Medium MaterialFiberglass

TypeCartridge Filter

MaterialAluminum Alloy

Housing Serve Lige15 Years

Filtration PerformanceFrom 5 μm To 0.01μm

Operate Temperature1.5~80ºc

Resistance CorrosionInside And Outside

Transport PackageBrown Inner Box & Cardboard

Filtration GradeMedium Filter

ColorLight Blue

ConnectionRc1"

Flow Rate7.2m³/Min

Maxi. Operate Pressure1.6mpa

EfficiencyF9

Element Serve Life4000~6000 Hours

ConfigurationStainless Steel Manual Ball Valve

Filter ElementTop & Bottom Cap With Stainless Steel

Connection & Wall Connection KitYes

SpecificationDimension: 120 X 113 X 459 Mm

梱包と配送
販売単位 : Piece/Pieces
パッケージ型式 : カートンボック
写真の例 :
製品の説明

産業用アプリケーションでのC ompressed空気が1Nmᶟに汚染記事の1億人以上が含まれています。これらの粒子のほとんどは、寸法が非常に小さく、5ミクロン未満であるため、コンプレッサーに取り付けられている標準の吸気フィルターで遮断することはできません。このような粒子は、圧縮中に生成された水や油の蒸気と混合して、アプライアンスの早期の摩耗を引き起こし、その結果、生産の費用のかかる中断の原因となり、維持が著しく増加します。


適切なエアフィルターを選択することで、システム全体のパフォーマンスを向上および向上させるために、処理する空気の量と必要なろ過度に応じて適切な機器を最適に選択できます。



エアコンプレッサーシステムに適したフィルターを選択するにはどうすればよいですか?

エアコンプレッサーを使用している場合、空気の浄化とろ過はメンテナンスの重要な部分です。圧縮空気フィルターは、産業用空気圧縮機システムで重要な役割を果たします。右のフィルタを選択するだけでなく、あなたのユニットの効率を向上させるが、それはまた、エネルギーコストを削減し、有害な化学物質や粒子状物質からあなたの従業員を保護することができます。

ただし、すべてのエアフィルターは圧縮空気システムで機能しますか?さて、それはあなたの労働条件、あなたが完了しているプロジェクト、そしてあなたがあなたの機器を使用する頻度に依存しています、あなたは正確な選択をする必要があるでしょう。このガイドでは、エアコンプレッサーフィルターの仕組み、重要な理由、購入するエアコンプレッサーフィルターの種類、交換時期について詳しく説明します

機能と進歩

①1.6Mpaの使用圧力、接続および壁キットが利用可能で、設置時間と費用を節約します。

②フィルターハウジングの15年保証、ダイカスト一体型技術のおかげ。

③ろ過精度は最大tp0.01μm、オイルミスト残留量は最大0.001mg /m³、ISO8573.1-2010規格に準拠したクラス1。

④圧力損失が低く、エネルギーを節約し、効率を高めます。




H FD 7つのグレードフィルター素子と直列:PF / AO / AA / AX / ACS / AR / AAR


PF AO AA AX ACS AR AAR
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21℃),1ppm(w). High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21),0.01ppm(w) Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21),0.001ppm(w) Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21)0.003ppmw Dust particles whose diameter more than 1μm can be removed Dust particles whose diameter more than 0.01μm can be removed




製品仕様書

Model) Pipe size Flow rates Dimension (mm)
L/S m³/min scfm W (Width) D  (Depth) H (Height) A B
HFD010 RC1/2" 16.7  1.0  35.3  90 82 255 37 179
HFD020 RC3/4" 25.0  1.5  53.0  90 82 255 37 179
HFD030 RC3/4" 30.0  1.8  63.6  90 82 286 37 212
HFD040 RC1" 33.3  2.0  70.6  90 82 286 37 212
HFD050 RC3/4" 46.7  2.8  98.9  120 113 359 53 269
HFD060 RC1" 60.0  3.6  127.1  120 113 359 53 269
HFD070 RC1" 80.0  4.8  169.5  120 113 459 53 369
HFD080 RC1-1/2" 120.0  7.2  254.2  120 113 459 53 369
Technical requirements Maximum operating pressure: 16 barg                                                                                                                      Maximum operating temperature: 80°C                  Minimum operating temperature:1.5°C

Pressure Barg 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Psig 15 29 44 59 73 87 100 116 131 145 160 174 189 203 219 232
Correction factor 0.38 0.53 0.65 0.76 0.85 0.93 1.00 1.07 1.13 1.19 1.23 1.31 1.36 1.41 1.46 1.51

coalescer fitler cartridge



圧縮空気フィルターの取り付け方法は?

1.取り付ける前に、フィルターの吸気口と排気口に接続されている圧縮空気パイプとバルブを清掃します。

2.メインパイプろ過とターミナルろ過の組み合わせを採用して、使用時のガス品質を確保します。

3.設置時には、フィルターの吸気口と排気口を水平に保ち、下水出口を下に配置する必要があります。フィルタのメンテナンスとフィルタエレメントの交換を容易にするために、垂直方向に一定のスペースを確保する必要があります。

4.スクリューエアコンプレッサーのフィルターは、ろ過された圧縮空気の品質に対するパイプラインの影響を減らすために、空気ポイントにできるだけ近い、換気された涼しい場所に設置する必要があります。

5.指定された使用圧力と使用温度範囲内で取り付けて使用し、空気の入口と出口の指示または矢印で示された方向に従って、粗い取り付けから細かい取り付けまで、すべてのレベルのフィルターを正しい順序で取り付けます。インストール中は、バイパスをできるだけ避けてください。空気中の油はフィルターの下流にバイパスされてパイプラインの内壁に付着するため、効果的な除去手段を見つけるのは困難です。

6.フィルターエレメントは定期的に交換する必要があります。交換時間を注意深く記録します。作業時間のZ 1が6 000時間を超えてはならないことをお勧めします

7.自動排水の排出時間は液体の水を排出するのに適しており、排出間隔はパイプラインの含水量に左右されます。

8.さまざまなグレードの圧縮空気フィルターに、お客様の要件に応じて、圧力損失ゼロのフローティングボールドレンバルブまたは手動バルブを装備できます。