Phamaceutical用の高品質の圧縮エアフィルター
$208.071-19 Piece/Pieces
$197.67≥20Piece/Pieces
お支払い方法の種類: | T/T,L/C |
インコタームズ: | FOB,CFR,EXW,CIF |
輸送方法: | Land,Ocean,Air,Express |
ポート: | Shenzhen,Guangzhou,Shanghai |
Ms. YUKA Filtration
何か私にできますか?
$208.071-19 Piece/Pieces
$197.67≥20Piece/Pieces
お支払い方法の種類: | T/T,L/C |
インコタームズ: | FOB,CFR,EXW,CIF |
輸送方法: | Land,Ocean,Air,Express |
ポート: | Shenzhen,Guangzhou,Shanghai |
モデル: YD058
Material: Aluminum Alloy
Housing Serve Lige: 15 Years
Element Serve Life: 6000~8000 Hours
Filtration Performance: From 5 μm To 0.01μm
Maxi. Operate Pressure: 1.0mpa
Operate Temperature: 1.5~80ºc
Connection: Rc3/4"
Flow Rate: 2.8m³/Min
Resistance Corrosion: Inside And Outside
Parts: Dp Indicator, Auto Drain, Sight Glass
Diversion Fin Design On Element Top Cap: Less Pressure Loss
Pressure Loss: About 0.25 Bar
Bleed Valve: Available
Color: Red
OEM & ODM Service: Yes
Trademark: Yuka
Transport Package: Brown Inner Box & Cardboard
Specification: Dimension: 120x 110x377mm
Origin: China
HSコード: 8421399090
Clapboard: Without Clapboard
Filter Number: 1
Medium Material: Fiberglass
Efficiency: F5
Filtration Grade: Medium Filter
Type: Cartridge Filter
販売単位 | : | Piece/Pieces |
パッケージ型式 | : | カートンパッケージ |
写真の例 | : |
The file is encrypted. Please fill in the following information to continue accessing it
あなたの圧縮空気は純粋できれいですか?
湿度の形でのほこり、さまざまな不純物、炭化水素、ワーザーは、大気中のair.compresssionプロセスに囲まれた主要な汚染剤であり、空気中の汚染の濃度を上げて、ビジネスの脅威を表しています。圧縮空気回路はこれらの汚染物質で満たされ、腐食はそのような問題の自然な効果としてもたらされます。 Yuka Line Air Filtersのおかげで、下流の機器を保護および維持します。
製品の概要
Commodity | Compressed air filter | |||||
Model | YD058 | |||||
Flow rate | 2.8m³/min | |||||
Element grade | 5μm/1μm /0.01μm/0.001mg/m³ | |||||
Working pressure | 143psi g | |||||
Working temperature | 1.5℃~80℃ | |||||
Material | Aluminum Alloy | |||||
Color of housing | Red | |||||
Trade term | EXW & FOB SHENZHEN | |||||
Package | Internal Box & External Carton | |||||
Warranty | 15 years for filter housing, 4000-6000 hours under rated working conditions for filter element | |||||
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m3/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
YD017 | RC1/2" | 16.7 | 1.0 | 35.3 | 89 | 79 | 246 | 40 | 186 | 118 |
YD025 | RC3/4" | 25.0 | 1.5 | 53.0 | 89 | 79 | 246 | 40 | 186 | 118 |
YD030 | RC1/2" | 30.0 | 1.8 | 63.6 | 89 | 79 | 280 | 40 | 220 | 158 |
YD035 | RC3/4" | 33.3 | 2.0 | 70.6 | 89 | 79 | 280 | 40 | 220 | 158 |
YD058 | RC3/4" | 46.7 | 2.8 | 98.9 | 120 | 110 | 377 | 55 | 276 | 195 |
YD068 | RC1" | 60.0 | 3.6 | 127.1 | 120 | 110 | 377 | 55 | 276 | 195 |
YD080 | RC1" | 80.0 | 4.8 | 169.5 | 120 | 110 | 477 | 55 | 377 | 290 |
YD145 | RC2" | 120.0 | 7.2 | 254.2 | 120 | 110 | 477 | 55 | 377 | 290 |
YD220 | RC1-1/2" | 200.0 | 12.0 | 423.7 | 162 | 151 | 676 | 64 | 566 | 480 |
YD260 | RC2" | 233.3 | 14.0 | 494.4 | 162 | 151 | 676 | 64 | 566 | 480 |
YD330 | RC2" | 267.2 | 16.0 | 564.8 | 162 | 151 | 984 | 64 | 875 | 780 |
YD360 | RC2-1/2" | 317.3 | 19.0 | 670.7 | 162 | 151 | 984 | 64 | 875 | 780 |
YD405 | RC2-1/2" | 367.4 | 22.0 | 776.6 | 200 | 189 | 757 | 78 | 634 | 560 |
YD430 | RC3" | 467.6 | 28.0 | 988.4 | 200 | 189 | 1012 | 78 | 634 | 560 |
YD620 | RC3" | 620.0 | 37.2 | 1313.6 | 200 | 189 | 1012 | 78 | 889 | 780 |
Technical requirements | Maximum operating pressure: 10 barg Operating temperature: 1.5°C~80°C. |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |